DOMINION® is a discreet, pierce-fixed flat panel cladding system that creates sleek recessed joints and a refined, architectural finish. Installed with a ventilated cavity, it can be laid vertically or horizontally for different design effects, making it ideal for both modern and traditional facades.
| Specification | 285mm Cover | 485mm Cover |
|---|---|---|
| BMT (mm) | 0.55 / 0.75 | 0.55 / 0.75 |
| Mass (kg/m²) | 6.07 (0.55) / 8.17 (0.75) | 5.47 (0.55) / 7.35 (0.75) |
| Nominal Cover Width (mm) | 285 | 485 |
| Rib Height (mm) | 25 | 25 |
| Minimum Roof Pitch | Not suitable for roofing (walling only) | Not suitable for roofing (walling only) |
| Fixings | Concealed clip system | Concealed clip system |
| Span Type | 285mm Cover 0.55BMT | 285mm Cover 0.75BMT | 485mm Cover 0.55BMT | 485mm Cover 0.75BMT |
|---|---|---|---|---|
| Single Span | 1200 | 1300 | 900 | 1000 |
| End Span | 1200 | 1200 | 900 | 1000 |
| Internal Span | 1500 | 1500 | 1200 | 1300 |
| Overhang | 100 | 100 | 100 | 100 |